MaintenancePublished 12 min read

Solar output has fallen, how do you narrow down the cause?

Editorial responsibility: Franck Tournier · Report a fix

TL;DR

Check the same period, actual generation and irradiation. Then compare similar days and inputs to see whether the pattern repeats.

Compare generation, irradiation and hourly profiles while monitoring is still active. Use a worked example to prepare evidence for the installer.

Illustration of a homeowner comparing two generation curves beside a window overlooking a solar roof in winter.
Illustration generated for this guide.
Adjusting the reference month for measured irradiation and comparing the hypothetical readings.
Adjusting the reference month for measured irradiation and comparing the hypothetical readings.

Your inverter portal is still receiving readings, but the solar yield looks unreasonably low. Start by checking a complete period, the correct generation measurement and the local weather. Then look for a pattern that repeats. A dull month across the whole installation calls for a different investigation from a single section that loses output every afternoon in clear conditions. Save the source files and note what has changed before requesting an inspection. The observations in this guide use information you can access from a safe position without opening a cabinet or going onto a roof.

This guide deals with a system that still reports measurements. If the application has stopped receiving data, begin with the guide to an offline solar app, which explains how to distinguish a communications outage from a loss of generation. If you see a warning for an electrical fault, smoke or visible damage, or smell burning, keep clear and follow the emergency instructions appropriate to that situation. An ordinary yield review can start with documents and a conversation with your installer.

Start with the right measurement

Check the unit in the interface. Kilowatts express power at a point in time or as an average over an interval. Kilowatt-hours express the energy accumulated over a period. The noon peak can be smaller while the daily yield remains similar. A healthy-looking peak followed by an abrupt drop in the afternoon can take a meaningful amount off the total. For the first check, use kilowatt-hours of photovoltaic generation by day and by month. Identify whether the displayed number is inverter output, grid export or electricity consumption. Export can be lower simply because a water heater, battery or other appliance takes more of the output on site.

Ask whether the measurement boundary changed. After installation of a battery, a monitoring platform can combine flows that were displayed separately before. A replacement inverter, another device or a new account can divide the historical record. Save the original export and mark the date of alterations. Keep absent entries distinct from measured zeroes. Filling every blank with zero can create an apparent drop that never occurred and give a contractor an incorrect starting point. Where available, use an independent cumulative meter to confirm the same amount of generation over the same boundary. For measurements at the connection point, the smart meter and energy management guide explains the direction and use of the readings.

Build a comparison with an appropriate baseline

Choose a completed calendar month and check the exact limits of each export. The portal may show local dates and deliver the file in another time standard. Confirm that both datasets describe the same equipment. If no part of the system has changed, the same month in an earlier year is usually more informative than an adjacent month. Roof shading, available daylight and solar elevation vary across seasons. Look at another previous year if the initial reference might have been unusually bright. Document days with incomplete records. For a narrower comparison, put the same hours from several clear days on one time axis, paying attention to local time changes and interval boundaries.

A planning estimate can be helpful where there is no history. Retrieve the agreed capacity, roof orientation, pitch, shading and loss assumptions. Check that the estimate models the roof you are using and whether later work changed its layout. The European Commission's Photovoltaic Geographical Information System provides climatic reference series and modelled production. A typical weather year provides a reference scenario. For a particular month, add information about the conditions actually observed at an appropriate location. A quotation may use values that are reasonable for long-term planning but insufficient to settle a claim about a specific period. Keep the design and operational records separate so you can explain both comparisons.

Bring in irradiation with its limitations visible

Look for a consistent series of measured or estimated solar irradiation covering both periods. A measurement at a known position in the plane of the modules is particularly useful. A regional dataset for a horizontal surface can offer context. Check how close it is to your elevation and surroundings. A local fog layer, a clear valley, a chimney and a snow-covered array could all produce different local outcomes from the monitored site. The MeteoSwiss climate report illustrates regional differences in global radiation. Use the period you are investigating when comparing your readings. A map of the annual average describes the year presented in the report. It cannot replace measurements for your month.

Treat the additional data as a clue. Irradiation and production are not perfectly proportional. Cell temperature, incidence angle, start-up thresholds and an inverter's limiting behaviour affect their relationship. An approximate relative calculation is useful when its boundaries are visible. Depending on where clouds and fog formed, scaling a rooftop result using a neighbouring valley can make the comparison worse. If the source has gaps or you cannot find a reasonably comparable series, leave the value blank. Give more weight to hourly shapes and dated evidence you can account for.

Worked example with a dull month and a persistent gap

Imagine a house that made 640 kWh in the reference month. The selected irradiation series showed 100 kWh/m². It fell to 83 kWh/m² in the corresponding month being reviewed. Multiply 640 by 83 and divide by 100 to get an adjusted reference of 531.2 kWh. If the portal reports 540 kWh, the absolute total is lower than in the reference month. Compared with 531.2 kWh, it is 8.8 kWh or about 1.7% above the rough adjustment. That calculation can help you prioritise a further review before commissioning work based on the monthly sum alone.

With the same irradiation series and an output of 420 kWh, the gap from 531.2 kWh is 111.2 kWh or about 20.9% lower than the adjusted comparison. These figures illustrate a method. You can turn to hourly curves, portal alerts and changes around the onset instead of treating a worked example as a fault threshold. Tell your installer how you selected the irradiation series and what equipment is included. If you have the installed rating, you can also divide kilowatt-hours by kilowatt-peak to compare specific yield in similar installations. This adjustment alone cannot make differently oriented roofs or measurement points equivalent and does not substitute for a performance assessment with suitable plane-of-array observations.

Check the profile before naming a cause

Choose several days with comparable clear conditions and align the hours. A west-facing array can reach its peak later. A short depression that moves with the sun can point to shading. A persistent gap at a specific time, a newly flat stretch or a missing input is worth documenting with the time and any accompanying notices. Compare export with output only after checking the building's use and the battery's behaviour. A flat export interval can have a distinct explanation from a flat generation profile. Grid limits, on-site demand and control settings can interact. Ask a qualified professional for the documented configuration and leave electrical settings alone while gathering evidence.

If the application shows several inputs, compare ones with similar orientation, geometry, modules and exposure. A string that spends its first hour behind a wall is a poor reference for an unobstructed slope. Where two comparable inputs separate unexpectedly, save views covering the same hours and identify the earliest visible difference. Swissolar's photovoltaic monitoring advice explains how hourly, monthly and annual readings can help reveal problems such as inverter or string failures. A pattern gives the installer a lead and a way to reproduce the observation. Further work may be needed to identify the affected component or a measurement issue.

Note physical changes and maintenance events

Look at the roof from ground level or another safe position. A rebuilt chimney, a growing tree, scaffolding, new rooftop equipment or snow on part of an array may be visible. Take photographs from the same place at informative times and record when you took them. A low winter sun can bring a structure's shadow onto modules that were previously clear. For a comparison in direct sunshine, find another similar day and include the temperature. Respect neighbours' property and avoid sharing images containing unnecessary identifying details. The guide to solar shading explains what to record when an obstruction regularly covers a section.

Compare the exports before and after a service visit. A software update, a new meter, renamed inputs and a brief interruption on the public network can affect the history in different ways. Check the time standard for events alongside the portal. Search for a piece of evidence that would challenge your first explanation. If only one of several comparable inputs is affected, local weather on its own may be inadequate. If the production counter remains normal and only a consumption or export display has changed, check measurement and building use before assuming an equipment fault. Keeping plausible alternatives visible makes a discussion with the installer more productive.

Send a package an installer can act on

Include exports for both periods, screenshots of dated hourly views, the installation reference, any drawing you have and the change log. Describe the change in a sentence that gives the dates, units and measured boundary. Mention uncertainty about a column, the representativeness of the weather data or the identity of a particular input. Indicate which roof area appears to be affected if there are several orientations. Keep passwords out of the initial report and agree a secure channel if narrowly scoped access is required. The Swissolar guide to operating photovoltaic systems describes common monitoring arrangements and information sources.

Ask what additional measurements would settle the issue, whether a visit is justified and how the installer will establish an outcome afterwards. A useful report identifies the part investigated, describes the checks performed and states which subsequent periods are comparable. A jump in production when sunny weather returns cannot assign the improvement to the work by itself. Keep the evidence from before and after in the same folder. If daily profiles remain consistent after adjusting for plausible conditions, schedule a further review. If a monitored input stops reporting or a meaningful change persists under comparable conditions, send the evidence promptly.

Preserve the original data and make your calculation repeatable

Export the readings before requesting a correction. Save the file with the date of download, the visible filter, the source name and the reporting interval. Use a copy for spreadsheet comments and calculations. Record which rows were excluded for incompleteness and how the file covers any time shift. Some exports include average readings; others report an interval total or an accumulating register. Ask the supplier which kind of column you have before aggregating it. Otherwise a spreadsheet can add power values, duplicate an hourly entry or silently combine local and universal times. If a neighbour agrees to a comparison, exchange an approximate normalised range without account identifiers. A clearly labelled notebook helps a second person reproduce the result after a firmware change or a transfer of ownership.

Use a follow-up window to tell whether the pattern changed

Decide in advance which observations you can repeat after a service call. Choose a time when the geometry of the sun and the weather should be similar. A weekday change in household routines can alter the grid flow even when the roof performs as before, so preserve a generation reading at the same time. Where trees or clouds cast fast-moving shadows, several comparable mornings can give more confidence than a single view. Ask whether the last available reports identify any limiting settings or active warning. In an enquiry, distinguish a continuing defect message from a historical notice. A careful timeline can reveal that an alarm appeared long before the visible reduction or began after the data source changed. The process gives you a concrete reason to request further professional checks or close the observation with a record of how the output returned to its expected range.

For a spreadsheet you expect someone else to use, keep a separate tab showing the checks you performed. Put measurement units in the column headings and place annotations beside the relevant dates. Colour a gap as incomplete instead of hiding it inside the chart. Sketch the roof orientation or attach the installer’s drawing so that a reader can match labels to equipment. Record the source and resolution of each weather series and whether its position was selected manually or suggested by a portal. When production varies with a temporary obstruction, add a dated note about when the obstruction appeared and was removed. A second reader can then distinguish a harmless temporary change from an ongoing pattern that merits inspection.

Sources

Frequently asked questions

Does one month of lower solar output show a fault?+

Check the same period, actual generation and irradiation. Then compare similar days and inputs to see whether the pattern repeats.

Sources & method

Swissolar, system monitoring · Swissolar, photovoltaic operating guide · MeteoSwiss, global radiation · JRC, climatic data and PVGIS